Bursa Transformer Operation Responsibility

Transformer operation responsibility service in Bursa and its surroundings: daily operation of the substation, maintenance plan, HV/MV/LV equipment controls, grounding and protection relay tests, oil analysis and official reporting. Safe and uninterrupted energy with EMO authorized electrical engineer.

Engineering FocusField ExperienceStandards AlignedEnergy EfficiencyFast Quotation24/7 SupportCertified TeamMeasurement & ReportingData-Driven Improvement
MV cubicle maintenance and testing work within the scope of transformer operation responsibility in Bursa
MV cubicle maintenance, function and safety checks at the substation — planned inspection.

Summary Highlights

  • Contracted transformer operation responsibility; record, document and care plan management
  • Annual inspection schedule and official report submission for the substation
  • Function and safety checks for MV switchgear, transformer, breaker, disconnector and protection relays
  • Condition monitoring with transformer oil, cooling, loading and thermal camera measurements
  • Measurement, test and compliance reports for grounding, lightning rod and internal installations
  • Personnel training, maneuver instructions and implementation of LOTO/OHS procedures
  • Emergency and fault management; contractual 24/7 communication and priority site visit
  • EDAŞ-EMO correspondence, application, acceptance and periodic inspection processes follow-up

Service Details

Transformer operation responsibility; In businesses with a substation and its connected MV/LV systems, an authorized electrical engineer is assigned to ensure the safe, uninterrupted and legal operation of the facility. This engineer, as the substation operation responsible engineer, manages all operation and maintenance processes on the field and often provides general SA operation responsibility It works integrated with its tasks.
Substations operating at high voltage (HV) level pose a serious risk of loss of life and property in case of malfunction or wrong maneuver. For this reason, not only the project planning phase but also the operation process requires expertise. The transformer operation responsible engineer undertakes both technical and administrative follow-up for the MV cubicles, transformers and main distribution panels in the facility; Perform testing and maintenance work on the HV/MV side when necessary. Bursa HV/MV testing, maintenance and repair plans with its service.
The first step in our transformer operation service is a detailed examination of the existing facility. MV cubicle layout, transformer power, protection scheme, grounding system, cable routes and LV main distribution panels are checked on site; Deficiencies and risky points are reported. Then, an annual inspection and maintenance plan is created and shared with the business. More detailed testing and oil analysis of the transformer itself is often Bursa transformer maintenance, testing and oil analysis It is designed together with our service.

Within the scope of the study; Visual controls of MV cubicles, transformers, breakers and disconnectors, mechanical operability tests, inspection of locking-grounding systems, function tests of protection relays and other measurements deemed necessary are carried out at regular intervals. This makes it possible to take precautions before a malfunction occurs.

The transformer operation responsible engineer handles not only the MV equipment but also the entire substation as a whole. Conditions that may shorten the life of the transformer are detected at an early stage through processes such as transformer oil and insulation system, cooling system, fan and pump controls, loading profile, and spot heating detection with thermal camera. These works are carried out by our technical maintenance team in the field. transformer testing and oil analysis evaluated together with its results.
Grounding (resistance/cellar) measurements, lightning rod and lightning protection system checks, main panel and internal installation conformity tests are also important headings within the scope of transformer operation responsibility. These measurements are prepared for occupational health and safety inspections. periodic inspection and inspection It is also supported by reports.
Transformer operation responsible engineer; Writes maneuver instructions, implements lockout–tagout (LOTO) procedures, and trains field personnel on the prohibition of working under voltage, grounding steps, and emergency scenarios. To reduce the risk of wrong maneuvers, verbal and written information is provided before each critical work. These processes are designed to be consistent with overall HV facility management. SA operation responsibility It is also associated with the framework.

Employer; It is obligatory to check that the engineer who will undertake the task has the Electrical HV Facilities Operation Responsibility Authorization Certificate issued by EMO, to provide the necessary personal protective equipment and test equipment, to allocate a budget for maintenance-repair and to implement the written instructions of the transformer operation responsible engineer.

The transformer operation responsibility service we offer in Bursa is carried out with a standard process consisting of the steps of discovery and current status report, preparation of an inspection schedule, periodic inspections, delivery of test-measurement reports and emergency support. Thus, we ensure that your substation is operated in accordance with both technical and legal requirements. In the field for transformer-specific maintenance and tests transformer maintenance, testing and oil analysis We work in coordination with our team.
In case of emergency, we offer 24/7 access, depending on the scope of the contract. We provide remote guidance in case of malfunction, outage, leakage current or equipment damage, and when necessary, we come to the site and manage the maneuvering and measurement processes personally. simultaneously if necessary HV/MV testing and maintenance With our service, we create detailed fault analysis and repair plans.
Transformer operation responsibility fee; It is determined on a project basis according to the total transformer power, number of transformers and MV cubicles, size of the facility, frequency of visits and the scope of the requested tests. In pricing, the current minimum wage tariff of the Chamber of Electrical Engineers is taken into account as the lower limit. Package according to need; SA operation responsibility and periodic inspection can be planned together with the services.
We provide transformer operation responsibility services for many industrial facilities, shopping malls, hospitals, hotels and large business centers, especially in Bursa, Nilüfer, Demirtaş, Kestel and surrounding organized industrial zones. Upon request, surveys and proposals can be made for facilities in nearby provinces. For project planning and institutional approval processes in new substation investments LV/MV/HV project design and consultancy We can offer end-to-end support with our team.

Legal basis of transformer operation responsibility; Electrical High Current Facilities Regulation and related standards published in the Official Gazette dated 30.11.2000 and numbered 24246. You can access detailed legislation information from the official links below:

https://www.emo.org.tr/regulations/regulations_Details.php?kod=37

https://regulations.gov.tr/regulations?MevzuatNo=14362&MevzuatTur=7&MevzuatTertip=5

Grounding and measurement studies for transformer operation responsibility in Bursa
Grounding measurements, periodic testing and reporting for transformers and MV equipment.

Frequently Asked Questions

What does a transformer operation responsible engineer do and why is it necessary?

Transformer operation responsible engineer; He is the authorized electrical engineer responsible for the safe operation of MV/LV equipment in the substation, creating a maintenance plan, carrying out tests and measurements, and recording all processes. In order to reduce malfunctions caused by wrong maneuvers and negligence and to ensure the safety of life and property, working with the transformer operator is necessary both legally and technically. Also for general HV facility coverage SA operation responsibility You can also benefit from our service.

Is transformer operation responsibility and HV operation responsibility the same thing?

Although the two tasks are often carried out by the same person, their focuses are different. High voltage operation responsibility While focusing on the general operational safety of the facility and compliance with the legislation, transformer operation responsibility covers transformer-specific topics such as daily monitoring of the transformer and its connected MV/LV equipment, maintenance plan, oil and insulation controls, thermal monitoring. Technical tests and oil analyzes of the transformer are mostly Bursa transformer maintenance, testing and oil analysis carried out by our service.

What tests and checks do you do?

We carry out operations such as visual and functional checks on the MV cubicle and transformer, grounding (resistivity/cellase) measurements, lightning rod and lightning protection system tests, thermal camera heating checks, transformer oil and insulation checks, protection relay tests, compensation and energy quality measurements on a planned schedule. For more detailed HV/MV level tests and cable/cell maintenance HV/MV testing, maintenance and repair Our service comes into play.

How is the fee determined?

We prepare a project-based proposal according to the total transformer power, number of transformers and MV cubicles, size of the facility, frequency of visits and the scope of the requested tests and measurements. In pricing, the annual minimum wage tariff published by EMO is taken into account as the lower limit. Offer if you want; periodic inspection and inspection together with or in general SA operation responsibility It can be prepared integrated with the package.

Can we take responsibility for operating transformers for facilities outside Bursa?

Our main service area is Bursa; We are especially concentrated in organized industrial zones. However, when it is suitable in terms of planning and logistics, we can also provide transformer operation responsibility or consultancy services to factories, energy facilities and large structures in nearby provinces. For the project planning and commissioning side in new installation or power increase projects LV/MV/HV project design and consultancy We work in coordination with our team.

Do you have emergency support?

Within the scope of the contract; We maintain an emergency procedure that includes a 24/7 contact line, preliminary assessment by phone or online, and a rapid site visit when necessary. In case of malfunction, leakage current, sudden heating or equipment damage, the transformer operation responsible engineer coordinates the process from start to finish; if necessary HV/MV testing and repair and transformer maintenance, testing and oil analysis An intervention plan is created together with our teams.